Supply pipe leak detection case studies

Published by ADI Leak Detection, with the engineer, the town, the methods and the outcome as recorded on the job. The photographs were taken on these jobs.

0333 567 2637Seven days a week, 7am to 9pm. Fixed price agreed before anyone travels.

The excavated driveway at Grantham, showing waterlogged soil around the buried lead supply pipe
The excavated driveway at Grantham, showing waterlogged soil around the buried lead supply pipe

A meter turning slowly, and old lead under the drive

Grantham, Lincolnshire

Robert Gires, ADI Leak Detection engineer

Found by Robert Gires

Based in South Yorkshire. 1,121 jobs completed.His profile

Property
Large semi detached house
Methods
Pressure testing, Tracer gas, Acoustic correlation, Visual inspection
Outcome
Underground mains leak located on the driveway, lead pipe repaired.

What the customer saw

The water meter had been turning continuously and slowly with no tap or appliance running anywhere in the house. Closing the internal stopcock made no difference. The meter kept going, which put the loss outside the house entirely.

How it was investigated

The internal cold pipework was pressurised to 5.5 bar with an air compressor and held for thirty minutes. No pressure was lost, so the inside of the house was ruled out. Tracer gas then went into the external supply and the ground above the pipe run was surveyed at the surface, with correlation equipment listening at the same time.

What was found

Tracer gas came up on the driveway close to the meter, and the acoustic trace agreed with it. Excavation at that point exposed waterlogged ground around an old lead supply pipe, leaking immediately next to the external stopcock.

What happened next

The damaged section of lead was cut out and replaced with new pipe and a universal transit coupling, and the supply was restored. Two recommendations followed: replace the external lead main in full given its age, and fit a pressure reducing valve, because the incoming pressure was high enough to put the internal pipework at risk.

Two independent methods agreeing on one spot is what turns a survey into a hole the width of a paving slab instead of a trench the length of the drive.

Published by ADI Leak Detection atcase-studies/water-mains-leak-detection-grantham/

Water spraying from the burst copper supply pipe once the garage floor had been opened up
Water spraying from the burst copper supply pipe once the garage floor had been opened up

A leak notice from the supplier, and a stopcock that would not shut

Liverpool, Merseyside

Matthew Barron, ADI Leak Detection engineer

Found by Matthew Barron

Based in West Yorkshire. 621 jobs completed.His profile

Property
Residential property
Methods
Acoustic correlation, Tracer gas, Damp meter, Pressure testing, Visual inspection
Outcome
Underground mains leak found in the garage, pipe repaired.

What the customer saw

A leak notice from the water supplier, water damage to the garage wall and the kitchen wall beside it, and the micro dial on the meter moving hard with nothing running in the house.

How it was investigated

The internal stopcock was passing water, so the quickest test available, shutting the house off and watching the meter, was gone. Tracer gas went in through a tap in the garage instead, and acoustic equipment listened for water moving through the structure.

What was found

Gas surfaced in the garage, the acoustic trace agreed, and the concrete floor was opened at that point to expose the pipe.

What happened next

The pipe was repaired during the visit.

A stopcock that no longer shuts off removes the fastest test there is. Everything after it takes longer, which is why a failed stopcock is worth mentioning when you call.

Published by ADI Leak Detection atcase-studies/water-mains-leak-detection-liverpool/

The blue supply pipe and its tee junction in the flooded excavation beside the meter box
The blue supply pipe and its tee junction in the flooded excavation beside the meter box

Water in the basement, and the fault outside the house

Marlborough, Wiltshire

Found by Artur Sowa

Based in Hampshire. 94 jobs completed.His profile

Property
Home with a basement
Methods
Supply tracing, Pressure testing, Acoustic listening
Outcome
Broken meter outlet fitting found and rebuilt; the source of the basement flooding removed.

What the customer saw

A flooded basement, and no internal stopcock anywhere in the property.

How it was investigated

The engineer found two external meter boxes and a stopcock hidden in an old gas box, then pressure tested and listened acoustically along the supply between the rear meter box and the external stopcock.

What was found

Excavation exposed a broken fitting on the outlet from the meter.

What happened next

The connection was rebuilt in 25 mm MDPE pipe and fittings, and the excavation was backfilled and made safe. ADI’s published record covers the pipe repair. It does not describe drying or restoring the basement.

Water appearing inside does not mean the fault is inside. On this job the first hour went on finding the isolation points, because a property with no internal stopcock has to be shut off from somewhere.

Published by ADI Leak Detection atcase-studies/water-mains-leak-detection-marlborough/

Your job will have its own complications

Every one of these had something that made it awkward. Describe yours and we will tell you what it means for the visit.

The office team speak to every customer before an engineer is booked, and the engineer who attends is the one who writes the report.